Vasai, Mumbai, Maharashtra
Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Dew Point Monitor, Portable Gas Monitor, Methane Gas Monitor, VOC Monitor, Dust Particulate Monitor, Gas Leak Monitor, Indoor Air Quality Monitor, LPG Gas Monitor, Industrial Oxygen Monitor, Hospital Oxygen Monitor, Confined Space Gas Monitor and Handheld Dust Monitor from Mumbai.
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Type | Online Dew Point Meter |
Brand Name | ATS |
Material | Plastic |
Shape | Rectangular |
Color | Black |
Usage | Lab Use |
Temperature Range | 50-100C |
Features | Anti Bacterial, Durable, Easy To Use, High Accuracy, Light Weight |
Meter Type | Digital |
Weight | 450 gm |
Power Supply | 3.7V |
Name | Dew Point Meter |
Brand name | Applied Techno Systems |
Application | Industrial |
Warranty | 1 Year |
1 Year | ASB Plastic |
Battery | LI-ION |
Measuring Range | -60 + 30 Deg C |
Display Type | LCD Display |
Data Logge | 32 Kbyte , Non-Volatile Memory |
Computer interface | RS-232 link for Data in ASCII Delimited Format, 9600 Baud, 8 Bits , 1 stop,1 start, No Parity. |
Display | 128x64 Graphics LCD |
Response time | 10 seconds for 63% step change |
Accuracy | 0 deg c to + 30 deg c = +/-1 deg c , -40 deg c to c deg c= +/-1.5 deg c, -80 deg c to 0 deg c = +/- |
Dew Point range | -60 deg c to + 30 deg c (Standered), -80 deg c to +30 deg c (Optional) |
Product Name | Portable Dew Point meter |
Product Code | 301D |
Port | Mumbai |
Payment Terms | T/T |
Delivery Time | Ex stock |
Packaging Details | special packing with pharmacol |
Preferred Buyer From
Location | Worldwide |
PORTABLE DEW POINT METER ( MODEL ATS 301D )
Applied portable handheld battery operated Dew Point meter model ATS-301D are designed to measures dew
point,Moisture and temperature faster and accurately over a wide measurements range .Model ATS-301D is highly
optimized to measure the dew point, moisture and Temperature for dryers and compressed air/gases.
Periodic monitoring of industrial Air systems results in a reduced maintenance cost & down time caused
bycondensate, the leading cause of corrosion in pneumatic systems.
Air or Gas samples up to 12kg/cm² pressure and temperature up to 75°C can be directly measured. For higher
temperature applications, a Heat sink tubing can be used. The meter can also be connected to a vacuum pump
forsampling from systems at low or atmospheric pressure.
ATS-301D Measures the dew point precisely by utilizing a highly reliable microprocessor based electronic circuit to
convert the sensor signal by the use of psychometrics equations. Assembled in a ABS plastic housing, It t sensor
manifold with an orifice that means line pressure for true pressure dew point readings
PORTABLE DEW POINT METER ( MODEL ATS 301D )
Robust & Reliably Construction for Industrial Applications
Instant Direct dew point reading
Multi Parameter Single 128 X 64 LCD Display
Over all range -80 deg. C to 30 deg.
Samples Pressure Upto 12 Kg/C2M
Inbuilt Thin film water vapour sensor
Optional RS 232 Computer Interface & Data Logger
Embedded software for moisture calculation in PPM
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Brand Name | Applied Techno Systems |
Usage/Application | Gas Leak monitoring |
Measurement Range | Standard |
Accuracy | +/-2% |
Display Type | Digital |
Gas Type | Natural Gas, Combustible Gas |
Power Source | Battery |
Product Code | ATS101M |
Preferred Buyer From
Location | Worldwide |
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Brand Name | Extech |
Gas Type | Natural Gas, Combustible Gas |
Detector Features | Battery Back-Up |
Display Type | Analog, Digital, Graphics |
Power Source | Plug-In, Battery |
Pump suction | > 4 hg Column |
Preferred Buyer From
Location | Worldwide |
Features :
Application :
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Application | Industrial Use, Laboratory Use |
Brand name | Applied Techno Systems |
Principle | Solid State Semiconductor and PID (Photo Ionization) |
Range | PPM, PPB |
Resolution | 0.1 Unit or 1 Unit (Application based) |
Sampling Method | Diffusion, Auto Suction or Direct Plug In |
Display | 128 X 64 Graphics LCD |
Alarm | Two Levels Low High, Visual and Audible |
Power Source | Built in Lithium Rechargeable battery |
Accuracy | +/2% |
Response Time | <5 Second |
Flow Rate | 2.84 L/M |
Data Storage | 1000 or 10000 |
Sensor Life | 2-3 Years |
Operating Time | 6 – 8 hours |
Product Code | ATS101M |
Preferred Buyer From
Location | Worldwide |
Features :
Environmental :
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Dimension | 153 x 120 x 122 mm (measuring head) |
Digital Output | USB RS- 485/ RS-232 |
Accuracy | + / - 2 % |
Ambient Operating Temperature | -20-+55 Deg C air temperature around the equipment |
Measuring Principle | Dynamic Detection Principle, DDP (Scintillation) |
Brand name | Dynoptic |
Display Type | Digital |
Application | Industrial |
Material | 316 Stainless Steel (powder coated) |
Product Code | DSL 340 |
Preferred Buyer From
Location | Worldwide |
FEATURES :
BENEFITS :
APPLICATIONS :
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Brand Name | ATS |
Measurement Range | 0-10 |
Display Type | Digital |
Response Time | 30 Seconds at 95% variation |
Portable | Yes |
Accuracy | Accuracy |
Battery Life | 2-3 Years |
Sensor | EC |
Range | 0-10 PPM |
Operating Temp | -5 to 55 deg |
Power Supply | Rechargeable Lithium Battery |
Sampling | Diffusion |
Product Code | 101M |
Preferred Buyer From
Location | Worldwide |
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Application | Industrial Use |
Brand name | Applied techno Systems |
Resolution | 0.1 Unit or 1 Unit (Application based) |
Range | PPM/PPB or mg/M3 |
Accuracy | 2% |
Response Time | <5 Second |
Product Code | ATS 208A |
Preferred Buyer From
Location | Worldwide |
Features :
Applications :
Other Details :
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Brand Name | Extech |
Gas Type | Combustible Gas, Natural Gas |
Detector Features | Hush Feature, Adjustable Sensitivity, Battery Back-Up |
Display Type | Graphics, Digital |
Power Source | Plug-In, Battery |
Accuracy | +/-2% |
Sampling | Diffusion |
Preferred Buyer From
Location | Worldwide |
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Voltage | 220V |
Features | High Speed, Smooth Function |
Warranty | 1year |
Data Storage Capacity | 500gb |
Brand Name | ATS |
Usage | Hospital, Clinic, Industrial |
Product Code | 101M |
Preferred Buyer From
Location | Worldwide |
Features :
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Type | Oxygen Monitor |
Brand Name | Applied Techno Systems |
Application | Hospital, Personal |
Color | white, blue |
Feature | Durable, Fast Processor, High Speed, Low Consumption, Stable Performance |
Voltage | 220V |
Condition | New |
Frequency | 50HZ, 60HZ |
Warranty | 2years |
Data Storage Capacity | 500gb |
Country of Origin | India |
Name | Oxygen Monitor |
Product Code | ATS101M |
Payment Terms | T/T |
Delivery Time | 1 Week |
Packaging Details | normal packing |
Preferred Buyer From
Location | Worldwide |
PORTABLE OXYGEN GAS PURITY ANALYZER MODEL ATS-101M
A COMPACT RUGGED & INTELLI GENT INSTRUMENT
SUITABLE TO CHECKING OXYGEN PURITY OF OXYGEN CONCENTRATOR
Its simple automatic operation, continuous measurement & digital display of purity
concentration makes it a valuable aid for onsite instant analysis & follow up action. Its
data logging & computer interface features can be used for further detailed analysis in the
Complete Automatic Operation
Self Diagnostic Check
Proven Sensor Technology
Continuous, Stable Alphanumeric Display
Inbuilt Suction Pump.
Long Life Rechargeable Batteries.
Data Logging and RS 232 Output Capability with
Recall Feature (Optional)
Intrinsically Safe.
the laboratory.
The Applied Portable Model ATS 101M with digital read out and alarms is a direct reading
compact Portable Gas Purity Analyzer, designed to serve the demanding field requirements of
various gases Producing and using Industry. It is designed to replace the cumbersome and time
consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers
the user a distinct advantage in terms of economy, dependability maintenance and ease of
operation. The instrument incorporate TCD / INFRARED as a transducer. It has adjustable
visual and audible alarms with Automatic Zero Calibration Feature.
On start up, the instrument automatically goes through complete self integrity check,
calibration check on demand. The press of sampling switch initiates the sampling through
inbuilt suction pump and digitally displays the results.
D E SDCERSIPCTRIOINPTION
D E SFCERAIPTTUIORNES
D E SOCPREIPRTAIOTNION
D E SACPRPIPLTIIOCNATIONS
AND OTHER MEDICAL APPLIANCES
Applied Techno Engineers Pvt. Ltd.
Website: www.appliedtechnosyste ms.net Email:info@appliedtechnosystems.net
104, Delta Industrial Estate, Building no.1, Bhoidapada, Ghokivare,
Sales & Administration Office:
Sativali Road, Vasai(E) Thane Dist-Palghar 401208 Maharashtra, India
+91 8652226750
Process Monitoring Instruments
An ISO 9001:2015 Company
Range
Minimum Resolution : 0.01 %
Readout : 128 x 64 Graphics LCD
Detection Principle
: Electrochemical
Accuracy
: +/- 0.5% of Full Scale.
Alarms : AudibleVisual Alarm for Low Battery.
Response Time : 10 Seconds at 95% variation
Warm Up Time
: 10 seconds.
Dimensions : 170(L) X 100(W) X 130(H)mm.
Weight : 500Gram with battery approx.
Accessories : Flow Meter, Rechargeable Lithium Battery with Charger.
Warranty : One Year.
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Power Source | Battery |
Display Type | Digital and Graphical |
Gas type | Natural and Combustible gas |
Brand name | Extech |
Product Code | ATS 101M |
Preferred Buyer From
Location | Worldwide |
Examples of confined spaces :
Atmospheric Hazards in confined Spaces:
Atmospheric hazards in a confined space are those that expose entrants to a risk such as death, entrapment, injury or acute illness from one or more of the following causes.
Applied confined space Entry Monitor:
The Applied CSE monitor is pre-set as an easy to use tool to comply with atmospheric testing. The APPLIED offers the flexibility to work effectively in a confined space while remaining protected from Oxygen combustibles, hydrogen sulfide, carbon monoxide and high or low oxygen levels.
Business Type | Manufacturer, Supplier, Retailer, Wholesaler |
Measuring principle | Optical scattering technology |
Light Source | Laser Diode |
Detection Range | 0.001 – 10mg/m3 |
Display | LCD |
Size Channel | PM10, PM2.5, PM1.0 |
Flow Rate | 2.83L/min (Imported Pump) |
Sample Time | 0-9999s Selectable |
Zero Count | <=10min |
Printer | External thermal printer |
Data Storage | 1000 |
Operating Time | 5 hours |
Outside Dim | 130*220*45(Wide*High*Deep) |
Weight | 0.6kg |
Environmental | -- |
Temperature | 15 degree Celsius |
Humidity | <85%RH |
Atmosphere Pressure | 86-106Kpa |
Preferred Buyer From
Location | Worldwide |
Applications:
Hi! Simply click below and type your query.
Our experts will reply you very soon.