Vasai, Mumbai, Maharashtra
Business Type | Manufacturer, Exporter, Supplier, Retailer, Wholesaler |
Type | Gas Sensor |
Material | Metal |
Certification | ISO 9001:2015 |
Click to view more |
Preferred Buyer From
Location | Worldwide |
Product Details
GAS MONITOR ( MODEL ATS 109TD EXP. PROOF )
FOR HYDROCARBONS/EXPLOSIVE, TOXIC GASES & OXYGEN.
H2,O2,CO,CO2,NO,NO2,SO2,H2S,NH3,CL2,E.O.,BR2,F2,HCL,HF,HCN
LPG/CNG,HYDROCARBONS,VOC,ORGANIC SOLVENTS/VAPOURS.
Fast and accurate response.
Flexibility to fit your application needs
··
· Compatible for Marine Applicaions
Integral or Remote mounting Sensor.
Interfaces with Industry Standard Transmitters. ·
·
· Ingress Protection IP-65
Applied Field proven gas Monitor/Transmitters continuously monitors for dangerous
concentrations of gases. The linearize 4-20 mA transmission can interface directly with any
receiving instrument starting from indicators, controllers to large control systems.
Provision for directly connection of buzzer/Hooter for Alarm through Relay.
The standard system consist of a compact electronic module housed in a Weatherproof or
explosion proof Metallic or Polyester box with an application specific sensor. This state
of the art transmitter is carefully designed with and manufactured with Industrial grade
Components for reliability accuracy and long life. It is certified for use in hazardous
areas Class 1, Division 1, Group B, C & D. (IIA, IIB or IIC), IP 65 apart from being
available in weatherproof Enclosure Transmitters are equipped with micro controller and
are heavily featured with self diagnostics, Auto calibration (in case of toxic, Oxygen,
combustible gases only) through embedded Software, can be done at site. RS 232/485 output
with baud rates of 2400 bps is available as an options.
With Display Without Display
CSIR-CIMFR
Approved
DESCRIPTION
SPECIAL FEATURES
Applied Techno Engineers Pvt. Ltd.
An ISO 9001:2015 Company
Process Monitoring Instruments
Gases Oxygen Hydrocarbon, Hydrogen
%
LEL PPM %
Range 0 - 25/30/100 0-100% 0-1000/10000 0-100
D etection Principle Electrochemica l Catalytic Semiconductor Thermal
Combustion Electrochemica l Conductivity
Gases H2S CO So2 NO2 2 Br2,F2 HCL HCN NO NH3 E.O
Range PPM PPM PPM PPM PPM PPM PPM PPM PPM PPM
Max 2000 4000/10% 200 50 2000 200 200 1000 100/500 100
Min 0 0 0 0 0 0 0 0 0 0
De t e c t i o n P r i n c i p l e Application Based Electrochemical , Catalytic, Semiconductor or PID
Gas Monitor, Gas Analyzer, Transmitters, Humidity Moisture Dew Point Analyzer, Dew Point
Transmitters, Sampling Systems & Dust Particulate Monitor
Response Time
< 30 seconds
Zero drift
0.2% FS
Accuracy
+/- 1% FS (For Oxygen 0.5% FS)
Operating Voltage
24 Volt DC or 230VAC
Operating Temperature -20 to +60 Deg. C
Terminations
PCB mounted terminal blocks to accept 1.5mm wires
Display
7 Seg. LED Display
Output
4-20 mA Linear, Relay for diff levels /0 - 1Volts DC (V)/RS232/RS485
2wire (Dry Electrochemical sensor based, Dew point, Humidity, Temp,
Moisture, Vapour Pressure) , 3Wire Combustible, VOC’s, Toxic Gases
Power Consumption
2 wire: 0.5 W max. / 3 wire: 3.6 W max.
Max. Load
600 Ohms
Mounting
Wall mounting, 2" Pipe (U clamps will be provided)
Note : Specifications and Features will vary with application. The above are established and validated during design, but are not to be construed as test criteria
for every product. Due to applied commitment to research, design and product improvement, specifications are subject to change without notice.
The Minimum & Maximum ranges & the Gases Indicated are Intended as a Guide for full scale detection.
VOC
PPM
100/1000
0
Housing Cast Aluminum Alloy (IP65)
Hi! Simply click below and type your query.