3.11 Lac / Piece(s)
Business Type Manufacturer, Supplier, Retailer, Wholesaler
Dimension 153 x 120 x 122 mm (measuring head)
Digital Output USB RS- 485/ RS-232
Accuracy + / - 2 %
Click to view more

Preferred Buyer From

Location Worldwide

Product Details

Ambient Operating Temperature
-20-+55 Deg C air temperature around the equipment
Measuring Principle
Dynamic Detection Principle, DDP (Scintillation)
Brand name
Dynoptic
Display Type
Digital
Application
Industrial
Material
316 Stainless Steel (powder coated)
Product Code
DSL 340

FEATURES :

  • Innovative Dynamic Detection Principle (DDP) measurement technique
  • Immune to gradual reductions in absolute intensity of the light signal soless susceptible to drift
  • Measurement reading as mg/m3 (when calibrated against standard reference measurements)
  • Rugged 316 stainless steel construction
  • Choice of interface options enabling easy integration
  • Free utility software for PC based set-up, control and data logging
  • Optional Operator Interface with different mounting configurations


BENEFITS :

  • Significantly less susceptible to drift than standard opacity monitors
  • Better accuracy over shorter path lengths, i.e. smaller duct diameter
  • Simple to install, commission and operate with an excellent reliability record
  • Rugged design with no moving parts so low maintenance
  • Latched head and lid design to enable ease of access for installation and maintenance THE TECHNOLOGY The DSL-340 Dust Monitor is an optical instrument designed to measure the concentration of dust or particulate matter in exhaust gas passing through a duct, stack or flue. The DSL-340 uses the innovative Dynamic Detection Principle (DDP) which measures fluctuations in the intensity of a light beam, using a folded beam Transceiver / Reflector arrangement. Increased dust or particulatedensity in the stack causes the amplitude of these fluctuations to increase. When calibrated against standard reference measurements, the amplitude of this signal relates directly to the dust concentration in the stack and this can be presented as a reading in mg/m³.


APPLICATIONS :

  • Cement works
  • Steel plants
  • Air filtration processes such as electrostatic precipitators
  • Other industrial applications with larger particle size and relatively high dust loading